27 Signet 8900 Multi-Parameter
Select the unit of measure for this pressure channel : psi bar kPa
P1 Units:
psi >
Select decimal location for this pressure display:
XXXXX. XXXX.X XXX.XX XX.XXX
T1 Units:
C >
Select the unit of measure for this temperature channel: °C or °F
9.5 Channel Settings: If Channel Type = Pressure
9.6 Channel Settings: If Channel Type = Temperature
Dampens display, output and relay response rates for this channel.
Off: Near instantaneous updates
Low: 4 s Med: 8 s Hi: 32 s
Dampens display, output and relay response rates for this channel.
Off: Near instantaneous updates
Low: 4 second averaging; Med: 8 second averaging; Hi: 32 second averaging.
P1 Average:
Med >
T1 Average:
Med >
If this Channel is PRESSURE and the sensor is 4 to 20 mA, set the minimum and
maximum setpoints.
If this Channel is TEMPERATURE and the sensor is 4 to 20 mA, set the minimum and
maximum setpoints.
4mA Set Point 1:
00.000 psi >
20mA Set Point 1
100.00 psi >
P1 Decimal:
**.*** >
4mA Set Point 1:
00.00 °C >
20mA Set Point 1
100.00 °C >